Problem: We're having difficulties having a DAG fire off given a defined interval. It's also preventing manual DAG executions as well. We've added catchup=False
as well to the DAG definition.
Context: We're planning to have a DAG execute on a 4HR interval from M-F. We've defined this behavior using the following CRON expression:
0 0 0/4 ? * MON,TUE,WED,THU,FRI *
We're unsure at this time whether the interval has been defined properly or if there are extra parameters we're ignoring.
Any help would be appreciated.
Solution
I think you are looking for is 0 0/4 * * 1-5
which will run on 4th hour from 0 through 23 on every day-of-week from Monday through Friday.
Your DAG object can be:
from airflow import DAG
with DAG(
dag_id="my_dag",
start_date=datetime(2022, 2, 22),
catchup=False,
schedule_interval="0 0/4 * * 1-5",
) as dag:
# add your operators here